hayward blue essence troubleshooting

By

hayward blue essence troubleshootingbluntz strain indica or sativa

I put a new 1 hp motor on the pump, and new mechanical seal in the pump, problem still the same. Salt Chlorinator Problems - Repair or Replace? - InTheSwim Pool Blog Thanks. Remove all of the bolts around the top and pull out the Filter Nest, or all of the fingers. Also check that the ground wire is firmly attached at both ends, on the motor and the plug. Step 1: Wait 60 seconds after the pump starts. it continues to cycle this way. Is it likely to be the pump or the AutoChlor switches and timer (which I replaced last year)? Got another one, it too is doing the same thing. Check the tightness on all wire connections, on the breaker, timeclock and motor. If clogged, open the pump up, and ream out the impeller vanes with a flexible wire. Hi Kathleen, sounds like a leak from the shaft seal, unless water is running out of the pump exit fitting, and running down the housing and dripping off the bottom. Checked everything still doesnt work . Probably not related to the water, but something is not right. Set the test meter to Ohms, of 1K or higher. Automatic restart 2 min after error is corrected. then I tried to switch it on again but the pump wont start. Do you believe I have a bad breaker? If it does make a humming or buzzing sound briefly and trips the breaker, check that the shaft rotates the impeller freely, and if so, replacing the capacitor is usually the fix. At this point, you can shut off power at the breaker, and pop the mechanism out of the box by depressing the tabs on the top, and inspect the gears and motor directly, for any insect problems, gecko tails (seen it!) Thank you for the quick response. It's a little over 3 years old and the cell checked out fine. Hi Michael, that could be a bad or weak capacitor, or a loose wire to the pump motor or to the outlet, or a bad power cord. The pump is working great but concerned about the hot cord. If any of these readings are outside limits, replace motor. Could be too much or too little sand, the filter should be about 2/3 full of sand. I put new sand it its still dumping could it have been sand still in the line what you think or is there anything else that could cause this I put 200 lbs of sand in which is the correct amount . https://twitter.com/inyopoolsFOLLOW us on INSTAGRAM! Hi Don, when its not an air leak, pump surging will then be an obstruction in the pipe, or filter, heater, check valve/filter valve/diverter valve, a bit of plastic usually (once I found a golf ball, in the skimmer pipe), that is pulled into a 90 or up against a port that is too small for the obstruction to pass. Got pump from a friend and he had no problems. Reprime the pump again, open water valves and test. Troubleshooting Your Hayward Aqua Rite System - http://bit.ly/2RC8myGHayward AquaRite Parts - http://bit.ly/2NPGXbjHow To Clean a Hayward AquaRite Turbo Cell - http://bit.ly/2TPpK5IStabilizer - http://bit.ly/3aCeEa7SUBSCRIBE for FREE swimming pool care and maintenance videos every week: http://bit.ly/SubscribeINYO ****VISIT our blog for weekly swimming pool tips, tricks, and more! From the salt water panel into electrical panel/ timer there are three cables (ground, common and hot). Thanks. Either way, when a DE filter clogs up quickly, it is either not enough DE powder being used, or the grids (flex tubes for Perflex) are clogged with mineral scale or oily deposits. Or a loose breaker. You will get much more visibility by. I have back washed the filter about 6 times in 1 month, and even soaked the filter (the DE fingers) in a cleaning solution and also soaked it in Muriatic Acid for about 30 minutes. last year, I replaced the Sand & O ring on the filter, and I resealed the O ring on both the filter & Pump with O ring lube. Perflex filters are particularly known (to me anyway) for building up oily deposits on the fingers or flex tubes, and clogging up quickly. Shut off power at the breaker to all pool equipment Open the door and inspect for debris with a mirror and flashlight. Can you help? type of, Kreepy type swimming pool cleaners - known as Suction Side Cleaners, are the simplest type of pool cleaner, and hence one of, Polaris Pool Cleaner Tune-Up Instructions I took a drive around the Beltway last weekend and opened cousin Joe's pool in Chevy Chase,, Troubleshooting Hayward Gas Heater Error Codes, Swimming Pool Covers: The Good, The Bad, The Ugly, Pool Cleaner Tune-Up Kreepy Type Pool Cleaner repair, https://www.google.com/search?client=firefox-b-1-d&q=hayward+h-150+manual, https://www.afternic.com/forsale/haywarddocs.info?utm_source=TDFS&utm_medium=sn_affiliate_click&utm_campaign=TDFS_GoDaddy_DLS&traffic_type=TDFS&traffic_id=GoDaddy_DLS. I am thinking it must be the age of the pump. When the control box is on, go to the diagnostics menu and give me the listed T-CELL type, amps, and voltage. One of them was arguably the best-constructed route from London [Marylebone] to Manchester. Step 2: Did you properly install your switch? If there's one thing for certain about pool equipment, is that they will all break down at some point in time. Spillover is just the spa filling up, and overflowing into the pool, a waterfall feature is something different, with dedicated plumbing and a booster pump usually. See if your test button has popped out on the outlet, or perhaps you have one on the breaker, a test/reset button. Hi Cindy, most likely an air leak. "height": "219",
Please consider. Is the wire size correct? Hi the strainer housing must need to be tightened up. I replaced the breaker and electrical plug which showed some damage but motor does not start and breaker still tripping Testing a Pool Pump's Capacitor If your pool pump is not starting, but instead gives a 'hum' or a 'nnngh!' Today,I cut the pipe off where the water leak was coming from and repaired it. Poseer una casa es la piedra angular de la riqueza tanto la riqueza financiera como la seguridad emocional. I just replaced a Hayward 2 hp SP2615X20 that started making a loud noise while still pumping, so I figured the bearings or something were gone, with a Hayward SP3015X20AZ 2 hp. For over 2 months, lots of troubleshooting, actually RE-PIPED THE SECTION FROM POOL TO PUMP done by professionalpump still will not primedraws water, wont primeplayed with outflow and values, no primetook apart (my nemesis) Hayward Perflex DE filter, cleaned fingers, silicone on gaskets, put back (I have done this crappy job a hundred times so I am familiar with the process)no primefeel like draining the damn pool and junking the whole thing >:(. Hi Shannon, the bolts are spinning. Home / Pool Equipment / Pool Heaters & Heat Pumps / Hayward Pool Heater Troubleshooting. However, when the filter is running for about 2-3 hours, the pressure increases to 20 psi, and the output water flow is minimal at best (extremely slow). Glad that you replaced the sand, normally lasts 5-7 years on larger sand filters, but filters below 21 diameter need it more often, and very small filters 12-14, need it almost every season. The filter caterige is brand new too. Pump Surging also occurs from low water level, or air leaks in front of the pump. Can you manually get it to rev-up on a higher speed? Tripping the breaker, could possibly be a bad breaker, allowing too much voltage to pass thru to the pump. I filled the pool to the level line, but the air bubbles stayed. Or it could be an obstruction in the impeller, or anywhere before the impeller (clogged pipe, small pipe, partially closed suction valves, air leak) all of which will produce lower than normal filter pressure. Note: Antimicrobial properties are built in to the blue filter media to inhibit the growth of bacteria that may affect this product. Read up on it and seems it happens a lot and the motor drive needs to be replaced. My Hayward Pump will pull the water through the basket really strong for about 45 seconds then the flow will stop for 20 seconds and the flow will then resume again. Does the mother board need replacing? The pool is only 15 months old and I have not had any problems since getting it installed May 2017, other than a small water leak coming from the non suction side of the pump. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
A start capacitor is supposed to only be energized for a few seconds to start the motor, and once the centrifugal switch opens and releases contact with the stationary switch, the capacitor is released. I disconnected it and plugged the Aquatrol in alone; that worked fine. Is there a trick to this? Any ideas as to how to fix this? Pump is 4yrs old. When it stops again, you may want to pull off the filter valve from the filter, and inspect the top few inches of sand, maybe replacing it with new. Question, if I can determine which return pipe is broke could I just block off that return and bypass it. Even though the motor is only 2 months old and had very little run time, bench running it sounds pretty horrible. could be the motor, if the shaft has worn unevenly, or if there are grooves or rust on the shaft. Holding the shaft stationary (so it wont turn), unthread the impeller, counter clockwise, to remove. For the green water, drop the pH to 7.2 and add enough shock until the water turns blue-ish, and run the filter 24/7. Now the backwash is leaking a small amount water and the pump seems to be surging instead of running smoothly. Hooked it up the same as the last motor and left the setting to 230 as that is what the last motor was set to run on. Could be a change in vibration, press down on the pump, to see if the tone changes. Another check to do is to place the multiport valve on recirculate, which bypasses the filter, and will let you know for sure that the problem is in the filter sand. Usually it takes about 15 mins, and the switch will reset and the motor will start again on its own. Our variable speed Hayward pump, when not running on highest speed, keeps resulting in FLO errors. Reset is immediate after error is corrected. If assumed to be the capacitor, get the MFD number printed on it, and find an exact replacement capacitor on our site, or from a local electric motor shop. Any suggestions? Zero on the gauge indicates no water flow, so if not an air leak it could be a clogged line, pump basket or impeller. Hi Theresa, if the pump is overheating, and shutting off for 20 minutes to cool down and then starting again, thats not usually a good sign, altho could be incorrect voltage or loose connections. Specialties: Cycling, Kickboxing, The Hayward Aqua Plus Automation System should have the capability to accommodate several T-Cell sizes. Old bronze pool pumps, like Sta-Rite and Anthony, that use Key Shaft motors with stub shafts need to be shimmed properly. Hi Carolyn, When a pump displays those symptoms, its usually an air leak or a collapsed suction hose, or a very dirty filter. Sun was beating on it. My pool is running, with water flow. Just be sure to buy the correct seal for your make/model pump, for the Powerflo Matrix pump, thats here: https://www.intheswim.com/p/hayward-spring-seal-w-seat-spx1250xz2c SPX1250XZ2C. Hi, might have been a small clog in the pipe. Once it finishes calibrating, cycle the main switch from AUTO to SUPER CHLORINATE and back to AUTO. If you have a multiport valve, set it on Recirculate, to bypass the filter, and rule out any problems there. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
), or the valves that are before the pump. "name": "In The Swim",
I assume from your post that there are 2 possibilities 1) bad capacitor (I assume I can spot it visually) or 2) frozen shaft or propeller (how do I spot it and fix it? The most common areas for an air leak are the pump lid (is it as tight as possible? I have a Hayward 1.65 variable speed pump it is on a timer for high and low. If the filter pressure goes higher when this happens, it could be an obstruction inside the filter or filter valve, or after the filter on the return line. Then there is often a switch or a timeclock that is wired in between the sub-panel and the pump. Hi again, I dont have a shaft seal replacement video, but there are many on youtube. We purchased a Hayward D.E Filter last summer. The small filter, usually at the wall? check that everything is tight and aligned. the pump is working but not priming. After we run the pump for a few minutes and then take the pump apart there is water in the impeller- but the water is where the seat housing is. This is why we usually recommend a larger cell than the cell rating would suggest. You say the pump is connected AFTER the filter? I changed my sand a few weeks and tested it and it worked fine. A hum sound is usually associated with a bad capacitor (motor rear, 9 oclock), however the capacitor is a battery that is only used on start-up, and is released within a second of start-up, but still could be related. If your cell looks like 4A, continue to Step 4. How can I secure the top to the filter so the water will not pour out of it while the pump is on filter mode? Diagnosing and Troubleshooting Your Hayward Aqua Rite System - INYOPools Another possibility could be a clogged pump impeller, should have mentioned that earlier. We opened our pool today, ran the pump for about 7 or 8 hours and the plug on the pump was actually melted to the outlet on our timer. If any of these readings are outside limits, replace motor. "name": "In The Swim",
Any idea? Ive had the pool for 25 years with no problems until now. what do you think the hum could be? Any suggestions?? Yes this pool was install without GFCI protection, (of course we will installing an equipment ground and GFCI Breakers.) Could be loose fitting on hoses. Thanks. The breakers still seem to be working since when I turn the breaker on and the timer switch for the pump, it does send power to the pump. Damaged or inadequate wiring, resulting in a power drop, are likely to blame for your Hayward pool pump shutting off. Thanks. Ive tried connecting direct from circuit breaker, as well as bypassing with a timer. Hi Dave..your honest opinion please..new 14000gal gunite pool with hayward sp3400vsp pump September 2014,ran a month winterized and ran fine for 3 years, when company came to open up the pool in 2017,pump stuck,installed new 3400@ $1200. Check for water under the display, or in the control box area. Tighten the fitting hand tight, plus 1/2 turn or so, until really snug, but not super-tight. Could it be a bad cord? Hi, it is either an air leak (a non-issue if installed below water level), or the suction pipes are too small for the pump size, or the hose may be collapsing inward under pressure. I noticed the pump wasnt running this week and saw the LED display was off and had moisture in it. Grab it and see if it looks/feels loose. Did not raise red flags, amature lol. Sounds like a leak from the shaft seal, although it could be dripping from the pipe carrying water out of the pump, running down and dripping off the bottom. IDXL2DB1930. Weve not had this issue the past 2 years (we bought the house 2 years ago). This time around I purchased the t-3 cell model since my pool is below 15k gallons. Then tighten the pump lid very tight. Repair or replace any tripped breakers or blown fuses. K-1766 Taylor Salt Test Jake, sounds like you got the filter up to speed. We have a Hayward ultra pro lx series pump for our above ground pool. My 2 year old 1.5 HP above ground Hayward pool pump worked fine last year. Gail, good luck! The pump is only one year old. If the set screws loosen, the impeller can slide forward and contact the pump housing, and grind both the bronze housing and bronze impeller down rapidly. Step 2: Select your product type. I assumed electrical issue but when I checked the voltage at the back of the motor and it was good I am at a loss. Still nothing. Motor again started humming and had to repeat the above steps each time I moved to backwash. I put the pump back together and it still leaks. My question to you is what to do from here. We would like to show you a description here but the site wont allow us.

Airbnb Shepherds Hut With Hot Tub Cornwall, Bryan Lee Funeral Home Angier, Nc Obituaries, Columbus City Schools Human Resources, 9 Foot Curtain Rod Without Center Support, Matthew "goodlooking Matty" Guglielmetti, Articles H

hayward blue essence troubleshooting

hayward blue essence troubleshooting

hayward blue essence troubleshooting

hayward blue essence troubleshooting